Walk any refinery or petrochemical plant in the Eastern Province and you will see calcium silicate on the hot lines. It has been the go-to high-temperature insulation for decades, and for good reason. It is strong, non-combustible and engineers know it well.
But “we have always used it” is not the same as “it is the best choice today.” Plants are tighter on space, energy is under closer watch, and corrosion under insulation (CUI) has become one of the costliest maintenance problems in the Gulf. That is why more project teams are asking a simple question: should we still specify calcium silicate, or is aerogel the better investment?
This guide compares the two side by side, using published manufacturer data, so you can make the call with real numbers.
Quick answer: Aerogel insulation such as Armacell ArmaGel XGH outperforms calcium silicate on thermal efficiency, thickness, weight, flexibility and moisture resistance. ArmaGel XGH conducts heat roughly 2 to 2.5 times less than calcium silicate across typical process temperatures, so the same heat loss can be achieved with a much thinner layer. Calcium silicate still makes sense where high compressive strength or mechanical abuse resistance is the top priority. For cryogenic and dual-temperature service, calcium silicate is not an option at all, while ArmaGel XGC covers -180°C to +250°C.
Table of Contents
What is calcium silicate insulation?
Calcium silicate is a rigid, moulded insulation made mainly of hydrous calcium silicate, usually with fibre reinforcement. It is covered by ASTM C533, which applies to surfaces from 27°C to 927°C. It came into use around 1950 as a replacement for asbestos-based insulation.
It is supplied as pre-formed pipe sections, curved segments and flat blocks. A typical Type I product, such as Johns Manville Thermo-1200, is rated to 650°C, has a dry density of up to 240 kg/m³ and a compressive strength above 690 kPa.
Where it shines:
- High compressive strength, so it handles foot traffic and pipe supports well
- Non-combustible
- Long track record and familiar to every insulation contractor
Where it struggles:
- It is rigid, so every bend, tee and flange needs cutting and fitting by hand
- It is not hydrophobic: the manufacturer says to jacket it as soon as possible because it only tolerates short rain exposure
- It is heavy and brittle, so breakage in transport and on site adds waste
- It is not designed for below-ambient or cryogenic service
What is aerogel insulation?
Aerogel is a solid made mostly of air, trapped in a silica structure with pores so small that heat struggles to move through it. In industrial insulation, the aerogel is bonded into a flexible fibre blanket that can be wrapped around pipes, vessels and equipment like a heavy cloth.
Armacell, the company behind ArmaFlex, makes its aerogel blankets under the ArmaGel name. The two products most relevant to energy facilities are:
ArmaGel XGH: hot service up to 650°C
- Thermal conductivity of 0.021 W/(m·K) at 24°C, rising to 0.043 W/(m·K) at 371°C
- Nominal density of 180 kg/m³
- Hydrophobic, and passes the ASTM C1763 water absorption test
- Non-combustible, Euroclass A2-s1,d0
- Compliant with ASTM C1728 Type III Grade 1A and IOGP S-738 (JIP33)
- Supplied in 5, 10 and 20 mm rolls, 1.5 m wide
ArmaGel XGC: cryogenic and dual-temperature service from -180°C to +250°C
- Stays flexible even at cryogenic temperatures
- Built for LNG, cold process lines and systems that cycle between hot and cold
- Can be layered with ArmaSound Industrial Systems for acoustic insulation
One point worth repeating from our earlier article: XGH and XGC are not interchangeable. Choose by operating temperature, and confirm thickness with a project-specific calculation.
Calcium silicate vs aerogel: side-by-side comparison
On almost every property that drives operating cost, aerogel comes out ahead. Calcium silicate wins on compressive strength.
| Property | Calcium silicate (Type I, e.g. JM Thermo-1200) | Aerogel (Armacell ArmaGel XGH) |
|---|---|---|
| Max service temperature | 650°C | 650°C |
| Thermal conductivity at 93°C mean | 0.056 W/(m·K) | 0.023 W/(m·K) |
| Thermal conductivity at 260°C mean | 0.078 W/(m·K) | 0.032 W/(m·K) |
| Density | Up to 240 kg/m³ | 180 kg/m³ nominal |
| Form | Rigid pipe sections and blocks | Flexible blanket, 5 to 20 mm |
| Water behaviour | Not hydrophobic; jacket promptly | Hydrophobic; passes ASTM C1763 |
| Fit around bends and flanges | Cut and mitred by hand | Wraps directly |
| Compressive strength | Above 690 kPa | Lower; needs proper support design |
| Cryogenic service | Not suitable | Yes, with ArmaGel XGC (-180°C to +250°C) |
| Fire | Non-combustible | Non-combustible (A2-s1,d0) |
Calcium silicate values: pipe insulation tested to ASTM C335, from the JM Thermo-1200 datasheet. ArmaGel values: ArmaGel XGH technical data, tested to ASTM C177.
Which performs better? The key differences explained
1. Thermal performance: aerogel loses far less heat
Thermal conductivity is the number that matters most, and here the gap is wide. Across the 38°C to 316°C range, ArmaGel XGH conducts heat about 2.3 to 2.5 times less than calcium silicate pipe insulation. At 371°C the gap narrows to about 2.2 times, and it is still a large margin.
In plain terms, every metre of hot pipe insulated with aerogel leaks less energy into the Saudi heat. That is fuel your boilers and heaters do not have to burn again.
2. Thickness and space: thinner for the same result
Because aerogel insulates better, you need less of it. As a rough flat-surface estimate, matching calcium silicate’s heat loss at around 260°C takes only about 40% of the thickness with ArmaGel XGH. Armacell itself reports ArmaGel can be up to 80% thinner than expanded perlite at the same thermal performance at 300°C.
This is a big deal on crowded pipe racks, offshore modules and brownfield revamps, where clearance between lines is already tight. Thinner insulation also means smaller jacketing diameters, so you buy less aluminium or stainless cladding.
3. Moisture and CUI: aerogel repels water
CUI is the hidden cost in Gulf plants. Humid coastal air, wash-downs and the occasional heavy rain all find their way under damaged cladding.
Calcium silicate is not hydrophobic. Its own manufacturer says it is only meant for short rain exposure and should be jacketed as soon as possible. ArmaGel XGH is hydrophobic and passes the ASTM C1763 water absorption test, so it helps keep the steel surface drier for longer.
No insulation removes CUI risk on its own. Good jacketing, sealing and inspection are still essential. But starting with a material that repels water gives your integrity team a better baseline.
4. Installation: flexible beats rigid
Calcium silicate arrives as rigid half-shells and blocks. Every elbow, tee, valve and flange means cutting, mitring and wiring pieces together, and breakage adds waste.
ArmaGel comes on a roll. Installers cut it with a knife and wrap it straight around fittings and irregular shapes. Fewer pieces, fewer joints and less offcut waste usually mean faster work on site, which matters during a tight turnaround.
5. Weight: lighter loads on supports
Calcium silicate weighs up to 240 kg/m³. ArmaGel XGH is 180 kg/m³, and you need much less of it by volume. The combined effect is a lighter insulation system, which helps on offshore platforms and older structures where every kilogram counts.
6. Temperature range: aerogel covers hot and cold
Both materials handle hot service up to 650°C. Only aerogel crosses into the cold side. ArmaGel XGC is built for cryogenic and dual-temperature service from -180°C to +250°C, which calcium silicate cannot do. For LNG and cold-process lines, that alone settles the comparison.
When does calcium silicate still make sense?
An honest comparison has to say where the older material holds its ground. Calcium silicate is still a sensible pick when:
- The insulation must carry heavy mechanical loads, such as walked-on surfaces or high-load pipe supports
- The line is easy to reach, straight and has plenty of clearance, so thickness does not matter
- A client specification or legacy standard names calcium silicate and cannot be changed
Many plants also use both: aerogel on congested, complex or CUI-prone sections, and rigid inserts at supports. A good supplier will help you decide where each one belongs instead of pushing one material everywhere.
Is aerogel worth the higher price?
Per square metre, aerogel blanket usually costs more than calcium silicate. But the purchase price is only one line in the total cost of an insulation system. A fair comparison looks at the whole life of the asset:
- Material cost: aerogel is higher per square metre, but you need less thickness and fewer layers
- Jacketing cost: a thinner system means smaller cladding diameters and less metal
- Labour cost: flexible blankets fit faster around fittings than rigid sections
- Energy cost: lower thermal conductivity means less heat lost every hour the plant runs
- Maintenance cost: a hydrophobic system helps reduce the CUI repairs and re-insulation that drive shutdown budgets
Add these up over 15 to 20 years of operation and the gap in upfront price often closes, or reverses. Our earlier article walks through a simple lifecycle cost approach you can use on your own project. The numbers always depend on your temperatures, pipe sizes and energy prices, so ask for a project-specific calculation before you decide.
Why this matters for Saudi Arabia and the GCC
Gulf facilities put insulation through a hard life. High ambient heat, coastal humidity, sand and long run times all test a system year after year. At the same time, Vision 2030 and the push for energy efficiency mean plant owners are being asked to do more with less fuel.
That combination favours aerogel. It cuts heat loss, frees up space on crowded sites, and stands up better to the moisture that drives CUI along the coast.
Buy Armacell ArmaGel from Gitco in Saudi Arabia
GITCO (Global Innovation Contracting Co.) is an authorised Armacell distributor and stockist in Saudi Arabia, based in Dammam. That means:
- Local stock: ArmaGel available in KSA, so you avoid long import lead times on urgent jobs and shutdowns
- Genuine product: supplied with Armacell certificates, test reports and compliance documents for your project approvals
- Technical support: help selecting XGH or XGC, layer build-ups and jacketing for your operating conditions
- Regional reach: offices in Saudi Arabia, Bahrain and the UAE to support projects across the GCC
Frequently asked questions
Is aerogel better than calcium silicate for high-temperature pipes?
On thermal performance, yes. ArmaGel XGH has about 2.2 to 2.5 times lower thermal conductivity than calcium silicate between 38°C and 371°C. Both are rated to 650°C, but aerogel reaches the same heat loss with a thinner, lighter and water-repellent layer.
How much thinner is aerogel than calcium silicate?
As a rough flat-surface estimate at about 260°C, aerogel needs around 40% of calcium silicate’s thickness for the same heat loss. Exact thickness depends on pipe size, temperature and design limits, so a project calculation is needed.
Does aerogel insulation prevent corrosion under insulation?
It helps reduce the risk. ArmaGel is hydrophobic and repels liquid water, while calcium silicate is not hydrophobic. Proper jacketing, sealing and inspection are still required.
Can calcium silicate be used for LNG or cryogenic lines?
No. Calcium silicate is designed for hot service. For cryogenic and dual-temperature lines, ArmaGel XGC covers -180°C to +250°C.
Is aerogel insulation more expensive?
It usually costs more per square metre. Savings on thickness, jacketing, labour, energy and CUI maintenance can offset that over the life of the plant.
What is the difference between ArmaGel XGH and ArmaGel XGC?
XGH is for hot service up to 650°C. XGC is for cryogenic and dual-temperature service from -180°C to +250°C. They are not interchangeable.
Where can I buy Armacell ArmaGel in Saudi Arabia?
GITCO in Dammam is an Armacell distributor and stockist in KSA. Contact info@gitco-sa.com for availability and quotations.
Conclusion: aerogel is the better long-term choice for most facilities
Calcium silicate earned its place on Saudi plants, and it still has a role where heavy loads and mechanical abuse dominate. But for most hot and cold service, aerogel performs better. It loses less heat, takes up less space, weighs less, installs faster and resists the moisture that drives CUI.
If you are planning a new project, a revamp or a shutdown, it is worth running the numbers on Armacell ArmaGel before you lock in the specification.
Talk to GITCO. Send us your operating temperature, equipment type, pipe sizes, current insulation thickness, project location and estimated quantity. Our team will help you choose between ArmaGel XGH and XGC and prepare a quotation from local stock.
Email: info@gitco-sa.com | Phone: +966 13 833 1753 | Head office: Dammam, Saudi Arabia
Pingback: Best Insulation for High-Temperature and Low Temperature Systems