ArmaGel DT is a high-performance flexible aerogel insulation blanket specifically designed for applications spanning cryogenic to dual-temperature ranges. This advanced material features a factory-applied aluminum foil facing, providing an excellent integrated zero-perm vapor barrier, crucial for preventing moisture ingress in demanding conditions. ArmaGel DT is compliant with ASTM C1728 Type IV, Grade 1A, ensuring high quality and reliability. Gitco-sa.com is a trusted authorized distributor of Armacell products, including ArmaGel DT, in Saudi Arabia and Bahrain.
The combination of flexible aerogel and the aluminum foil facing offers superior thermal performance and exceptional protection against moisture. Its low thermal conductivity minimizes heat gain or loss across a wide temperature spectrum, from -196°C (-292°F) up to 250°C (482°F). The integrated vapor barrier simplifies installation and ensures long-term insulation integrity. ArmaGel DT is hydrophobic, exhibits low water vapor sorption, and is non-corrosive to steel. It also meets IMO standards for surface flammability and smoke generation & toxicity.
Key Features of ArmaGel DT:
- Cryogenic and Dual-Temperature Application: Suitable for a wide temperature range (-196°C to +250°C).
- Factory-Applied Aluminum Foil: Provides an excellent integrated zero-perm vapor barrier.
- ASTM C1728 Compliant: Meets stringent industry standards.
- Flexible: Easy to handle and install, even at low temperatures.
- Ultra-Low Thermal Conductivity: Minimizes heat transfer for maximum energy efficiency.
- Hydrophobic: Repels water and resists moisture absorption (≤ 8%).
- Non-Corrosive to Steel: Safe for use with various piping and equipment materials.
- Compliant to IMO Standards: Meets fire safety requirements for marine applications.
- Fungal Growth Resistant: Inhibits the growth of mold and mildew.
Product Variations of ArmaGel DT:
ArmaGel DT is available in flexible blanket form. While the provided data doesn’t specify exact thicknesses and roll dimensions, variations typically include:
- Different Thicknesses: To meet various thermal insulation requirements for cryogenic and dual-temperature applications.
- Standard Roll Widths and Lengths: Designed for efficient coverage of pipes, vessels, and equipment.
Please contact Gitco-sa.com for detailed information on available thicknesses, roll sizes, and specific product codes for ArmaGel DT in Saudi Arabia and Bahrain to meet your project’s specific thermal and mechanical requirements in cryogenic and dual-temperature environments. For industrial applications, an appropriate outer covering may be recommended for added mechanical protection; consult with Gitco’s technical services for specific guidance.
Applications of ArmaGel DT:
- Cryogenic Insulation (LNG, etc.)
- Dual-Temperature Systems
- Energy Sector (pipelines, storage tanks)
- Industrial Facilities with both hot and cold processes
- Marine Applications
- Acoustic Insulation (as a component in layered systems where a vapor barrier is needed)
ArmaGel DT – Frequently Asked Questions
- What is ArmaGel DT?
ArmaGel DT is a flexible aerogel insulation blanket specifically designed for cryogenic and dual-temperature applications. - What makes ArmaGel DT suitable for dual temperatures?
It is engineered to perform reliably across a wide temperature range, from -196°C (-321°F) to +250°C (+482°F), including cyclic operation. - What is the thermal conductivity of ArmaGel DT?
Its declared thermal conductivity (λd) at 24°C (75°F) is ≤ 0.021 W/(m·K), offering superior insulation performance. - Does ArmaGel DT have a built-in vapor barrier?
Yes, ArmaGel DT features an integrated zero-perm vapor barrier, providing excellent resistance to moisture ingress. - Is ArmaGel DT hydrophobic?
Yes, ArmaGel DT is hydrophobic, repelling liquid water and helping to prevent corrosion under insulation (CUI). - What are the typical applications for ArmaGel DT?
It is used for insulating pipes, vessels, and ducts in cryogenic, offshore, industrial (typically oil and gas), and process equipment facilities. - In what thicknesses is ArmaGel DT available?
ArmaGel DT is available in thicknesses of 5 mm, 10 mm, 15 mm, and 20 mm. - Is ArmaGel DT flexible and easy to install?
Yes, it is a flexible blanket that can be easily cut and conformed to various shapes, simplifying installation. - Is ArmaGel DT lightweight?
Yes, its nominal density ranges from 160 to 240 kg/m³, making it lighter than traditional insulation. - Does ArmaGel DT offer acoustic insulation properties?
Yes, it can be used as a component of ArmaSound Industrial Systems to provide acoustic insulation. - What is the fire performance rating of ArmaGel DT?
ArmaGel DT has a surface burning characteristic of FSI < 25 and SDI < 50 according to ASTM E84 and is compliant with IMO Part 2 and Part 5. - Does ArmaGel DT help prevent corrosion under insulation (CUI)?
Yes, its hydrophobic properties and integrated vapor barrier help mitigate the risk of CUI. - Is ArmaGel DT compliant with industry standards?
Yes, it is compliant with ASTM C1728 Type IV, Grade 1A and meets IMO standards. - Is ArmaGel DT suitable for multi-layer applications?
Yes, it is suitable for use in multi-layer applications with other insulation products. - Does ArmaGel DT pass corrosiveness tests for steel?
Yes, it passes corrosiveness tests according to ASTM C1617. - What are the key benefits of using ArmaGel DT?
Key benefits include superior thermal performance, flexibility at cryogenic temperatures, an integrated vapor barrier, CUI mitigation, and acoustic capabilities. - What is the water absorption rate of ArmaGel DT?
ArmaGel DT has a water absorption rate of ≤ 8% according to ASTM C1763. - What is the linear shrinkage under soaking heat for ArmaGel DT?
It exhibits < 2% linear shrinkage in width and length under soaking heat. - What is the compressive strength of ArmaGel DT?
It has a compressive strength of > 5 psi (34.5 kPa) at 10% compression. - Why should I choose ArmaGel DT for my cryogenic and dual-temperature insulation needs?
ArmaGel DT offers a reliable and high-performance solution with excellent thermal properties, an integrated vapor barrier, hydrophobic characteristics, and acoustic benefits, specifically designed for the demanding conditions of cryogenic and dual-temperature applications.
For superior thermal performance and an integrated vapor barrier in cryogenic and dual-temperature applications, choose ArmaGel DT from Gitco-sa.com, your authorized Armacell distributor in Saudi Arabia and Bahrain.
Brand
Armacell
| Property | Value / Assessment | Standard / Test method | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Temperature range | |||||||||||||||||||||||||||||
| Service temperature1 |
|
ASTM C411 | |||||||||||||||||||||||||||
| Thermal conductivity | |||||||||||||||||||||||||||||
| Declared thermal conductivity2 |
|
ASTM C177 | |||||||||||||||||||||||||||
| Temperature resistance | |||||||||||||||||||||||||||||
| Linear shrinkage under soaking heat | < 2% in width and length | ASTM C356 | |||||||||||||||||||||||||||
| Fire Performance and Approvals | |||||||||||||||||||||||||||||
| Surface burning characteristics | ≤ 25 flame spread index ≤ 50 smoke development |
ASTM E84 | |||||||||||||||||||||||||||
| Surface flammability | Compliant to IMO Part 5 | IMO 2010 FTP Code, Part 5 | |||||||||||||||||||||||||||
| Smoke generation and toxicity test | Compliant to IMO Part 2 | IMO 2010 FTP Code, Part 2 | |||||||||||||||||||||||||||
| Resistance to water vapour | |||||||||||||||||||||||||||||
| Water vapour sorption | ≤ 5% by weight | ASTM C1104 | |||||||||||||||||||||||||||
| Water vapour permeance of integrated vapour barrier | 0.00 perm | ASTM E96 | |||||||||||||||||||||||||||
| Resistance to water | |||||||||||||||||||||||||||||
| Hydrophobic | Yes | ||||||||||||||||||||||||||||
| Water absorption | ≤ 8% | ASTM C1763 | |||||||||||||||||||||||||||
| Corrosion mitigation | |||||||||||||||||||||||||||||
| Corrosiveness to steel | Passed, Mass Loss Corrosion Rate (MLCR) not exceeding that of 5 ppm chloride solution on carbon steel coupon | ASTM C1617, Procedure A | |||||||||||||||||||||||||||
| Stress corrosion cracking | Passed | ASTM C692, ASTM C795 | |||||||||||||||||||||||||||
| Physical attributes | |||||||||||||||||||||||||||||
| Nominal density | 185 kg/m³ (11.5 lb/ft³) | ASTM C303 | |||||||||||||||||||||||||||
| Mechanical properties | |||||||||||||||||||||||||||||
| Compressive strength3 | ≥ 5 psi/ 34.5 kPa at 10% compression | ASTM C165 | |||||||||||||||||||||||||||
| Flexibility of insulation blankets | Flexible | ASTM C1101 | |||||||||||||||||||||||||||
| Weather and UV resistance | |||||||||||||||||||||||||||||
| Weather resistance | In all industrial applications the outer layer of the material must be protected with an adequate covering like metal jacketing or preformed UV-cured GRP (Glass-Reinforced Plastic) cladding. Please contact Technical Services for guidance on the temperature limitations and specific construction considerations which need to be made for each jacketing system. | ||||||||||||||||||||||||||||
| Health and environment | |||||||||||||||||||||||||||||
| Fungal growth | No growth | ASTM C1338 | |||||||||||||||||||||||||||
| Health aspects | Neutral | ||||||||||||||||||||||||||||
| Other technical features | |||||||||||||||||||||||||||||
| Shelf life4 | Max. 3 years | ||||||||||||||||||||||||||||
| Storage | Material shall be stored indoors, in clean and dry conditions, away from direct sunlight. | ||||||||||||||||||||||||||||
|
1 For operating temperatures below -180°C, special attention must be given to the system design and craftsmanship during installation to ensure that the material does not come in contact with liquid oxygen. For further information and support, please contact Technical Services. 2 Measured under a load of 1.5 kPa (0.22 psi). 3 Test performed with a preload of 13.8 kPa (2 psi). 4 Shelf life (maximum storage time) is limited to ensure that only currently manufactured products are installed on projects. This limitation is restricted solely to storage of the product and does not affect the lifetime of product after it has been installed. |
|||||||||||||||||||||||||||||